NÅNO Applications
Liquid Flow Computer
- Volume correction for Crude & Refined Products, API MPMS Ch 11.1 2012 and 1980, Tables A & B, NGL with TP27/API 11.2.4 & TP15, and water
- Multi-product, up to 12 individual product types with MF per product
- Baseline & Proved meter factors management per product or a Reynolds number corrected MF can be applied when used with an Endress + Hauser Promass 300 Coriolis meter
- Single 10 Point K-Factor linearization with override
- Both Pulse Fidelity and Line Integrity options can be selected
- Support for a Fast Loop or Header density meter, with separate T & P corrections
- PID analog output based upon either the Main flow meter flow rate or to control the Fast Loop (slipstream or bypass) flow rate
- Optional Local Panel (and web browser mimic) with configurable security for meter technician interface
- Built in data logger and graphical trending display, downloadable for spreadsheet analysis
- Batch initiation via website, Modbus, XML comms, Local Panel display, digital input or calendar events
- Support for Single or Dual samplers
- Sophisticated Alarm system with critical data logging and additional user configurable Alarms
- Densitometer interface with a range of inputs. These can be analog, period mode (with Solatron calibration constants) or Digital Communications from a Coriolis meter
- Snapshot report with instantaneous values and a selectable rolling average period for Density, Temperature & Pressure (for pycnometer verification)
- Low frequency cut off for meter input
- Support for multiple printers, serial and networked, and reports can automatically uploaded to an FTP site, and the optional SD Card
- Browser based PC interface for programming. No special software needed
- Hourly, Daily, Monthly, Batch, Proving and Meter Tech reports
Unified Prover
- Small Volume prover and Ball provers supported
- Volumetric and Gravimetric based proving
- Volume correction for Crude & Refined Products, API MPMS Ch 11.1 2012 and 1980, Tables A & B, NGL with TP27/API 11.2.4 & TP15
- Repeatability or uncertainty based automatic proving configurable
- Proves can be initiated directly using the local operator panel (or browser), from an HMI, via Modbus or from a NÅNO Liquid Flow Computer
- Supports 12 meter runs in integrated operation
- Can be operated standalone, driven from the HMI or tightly integrated with the NÅNO Liquid Flow Computer
Master Meter
- Mass to Mass, Mass to Inferred Mass and Volume to Volume comparisons
- Inferred Mass and Volume to Volume modes use volume correction for Crude & Refined Products, API MPMS Ch 11.1 2012 and 1980, Tables A & B, NGL with TP27/API 11.2.4 & TP15
- Densitometer interface with a range of inputs. These can be analog, period mode (with Solatron calibration constants) or Digital Communications from a Coriolis meter
- Master Meter Prove runs can be completed by reaching a specified Quantity (Mass/Volume), Pulse Count, Time or Manual Trigger
- Repeatability is calculated by average meter factor method, and the number of good runs and repeatability are user selectable
- Prove cycles can be initiated using the Local Panel, the web interface or communications
Differential Pressure Gas Glow Computer
- Single, Low-High or Low-Medium-High pressure cells
- ISO5167 (1991, 1998 and 2003) or AGA3 Flow Calculation
- AGA 8 Detailed, Gross Methods 1 & 2
- ISO6976, GPA 2172 or AGA5 Heating Value Calculation selectable
- Flange, Corner or D/D2 Tapping, ISA1932 Nozzle and Venturi options
- Cone meters also supported
- Upstream or downstream temperature location
- Support for Orbital Gas PT2 or Daniel 2350 chromatograph Modbus map
- Metric and US Customary measurement units
Gas Turbine Flow Computer
- Supports Gas Turbine, Ultrasonic and other volumetric pulse meters
- AGA7 Flow Calculation
- AGA8 Detailed, Gross Methods 1 & 2
- ISO6976, GPA 2172 or AGA5 Heating Value Calculation selectable
- Support for Orbital Gas PT2 or Daniel 2350 chromatograph Modbus map
- Metric and US Customary measurement units
Integrated LACT Controller
- One box solution for Measurement, Control & Driver interface
- Fully API compliant
- LACT or ACT/Offloading
- Multiple samplers handled
- Tickets can be printed locally and/or remotely, and/or transferred via FTP
- FlowCal TFX supported
- Continuous Produced Water measurement
- Can utilise TA1000 type Thermistor temperature sensors
Sampler System Validation Package
- Automates the sampler verification process
- Can be used with a single oil meter system, or a station with up to 6 oil meters
- Water Injection can be upstream or downstream of the oil meter(s)
- Local Panel operation and configuration
- Transmitter Bias Adjustment from Local Panel
- PID Control of water injection flow rate
- Pre & Post Injection Baseline check
- Pre, Post & Average checks against Sampler titration results
- Detailed Sampler Test Report
- Hourly Oil & Water reports and on-demand snapshot report
Other Miscellaneous Applications...
- Marine loading / off-loading
- Netoil Flow Computer
- Hydrostatic tank gauging and loading application